48
• SEQUENCE POINT
Up to 32 points can be specified for each sequence line. The sequence points
represent the order of the preset points that the dome wiII automatically run.
The following setup items, including PRESET POSITION, SPEED and DWELL
TIME, wiII influence how the camera runs through each sequence point.
• PRESET POSITION
Users can assign a specific preset position to the selected Sequence Point with
this item. Options include "1-256" and "END." END is used for the Sequence
Point following the last Sequence Point when the amount of sequence points
(see the previous section) is less than 32 points.
NOTE:
If not all 32 points are used, please set the point following the last
Sequence Point as "END" (PRESET POSITION) so that the sequence
line can work properly. For example, if a user intends to set a Sequence Line
with 5 sequence points
L
t is required to set the PRESET POSITION of
Sequence Point 06 as "END."
• SPEED
Users can set the pan/tiIt speed of the dome camera from one sequence point
to the next one, and the range of setup speed is from 1 to 15. Within the range,
PAN speed varies from 10 ~ 400 (degree/sec.) and TILT speed varies from 8 ~
400 (degree/sec.).
• DWELL TIME
The DWELL TIME is the duration time that the dome camera wiII stay at a
sequence point and the range is from <0> to <127> seconds. The dome
wiII go to the next sequence point when the DWELL TIME expires. If the
setting is <0>, the dome camera wiII stay at this sequence point for less
than 1 second and then shift to the next point.
• RUN SEQUENCE
Users can command the dome camera to run the selected sequence line
manually. Press the
<CAMERA OFF>
button to execute a sequence line.
• EXIT
Select the item to exit the SEQUENCE menu; go back to
MAIN PAGE 2
to
carry on setup of autopan.