14
IMPIANTO IDRAULICO - PLUMBING SySTEM - INSTALLATION HyDRAULIqUE - HyDRAULISCHE ANLAGE -
INStALAcIóN HIDRáuLIcA - ГИДРАВЛИЧЕСКАЯ СИСТЕМА - ΥΔΡΑΥΛΙΚΟ ΣΥΣΤΗΜΑ -
水力设备
Technical data for the plumbing system:
- Minimum working pressure: 2 bar
- Working pressure: recommended operating field 3 ÷ 4 bar
- Maximum working pressure: 5 bar (Install a pressure reducer for higher hydraulic pressures)
- Maximum working temperature: 65°c
- Floor waste required with capacity ≥ 60 l/min.
- 8,8 kg empty weight of the complete head shower (with water about 9,3 kg)
Data for plant dimensioning
Feeding pipes for the shower system [A1 - A2 - A3]: minimum internal diameter 12 mm
Static
pressure
[ bar ]
Minimum required feeding
for a correct working of the shower system
( 1 )
Rain Function [A1]
[ l/min ]
( 2 )
Cascade Function [A2]
[ l/min ]
( 3 )
Water Spray Function [A3]
[ l/min ]
2
22
17
It is not
binding
3
21
16
4
20
15
5
19
14
( 1 ) Minimum delivery from head shower for the correct working “Rain”: 13 l/min [ B1 ].
( 2 ) Minimum delivery from head shower for the correct working “Cascade”: 11 l/min [ B2 ].
( 3 ) Minimum pressure for the correct working “Water spray”: > 2 bar.
Data for boiler and waste dimensioning
Static
pressure
[ bar ]
Maximum delivery for the shower system
fed with internal 12 mm Ø pipes
Rain Function [B1]
[ l/min ]
Cascade Function* [B2]
[ l/min ]
Water Spray Function [B3]
[ l/min ]
2
16 [ with limiter ]
16
0.8
3
16 [ with limiter ]
16 [ with limiter ]
1
4
16 [ with limiter ]
16 [ with limiter ]
1.2
5
16 [ with limiter ]
16 [ with limiter ]
1.3
(*) For the correct working of the cascade, with working pressures ≥ 3 bar always install a flow limiter (16
l/min).
ING
Summary of Contents for 40442
Page 21: ......
Page 28: ...28 INSTALLAZIONE INSTALLATION INSTALLATION INSTALLATION INSTALACI N Fig 10 Fig 11 D E 2 5 mm F...
Page 30: ...30 INSTALLAZIONE INSTALLATION INSTALLATION INSTALLATION INSTALACI N Fig 12 Fig 13 G H...
Page 32: ...32 INSTALLAZIONE INSTALLATION INSTALLATION INSTALLATION INSTALACI N Fig 14 Fig 15 30 mm 4 mm...
Page 38: ......
Page 41: ...41 MANUTENZIONE MAINTENANCE ENTRETIEN WARTUNG MANUTENCI N...
Page 44: ...44 MANUTENZIONE MAINTENANCE ENTRETIEN WARTUNG MANUTENCI N Fig 25 Fig 27 Fig 26 R...
Page 46: ...46 MANUTENZIONE MAINTENANCE ENTRETIEN WARTUNG MANUTENCI N Fig 28 Fig 29 2 5 mm...
Page 51: ...51 MANUTENZIONE MAINTENANCE ENTRETIEN WARTUNG MANUTENCI N CN...
Page 52: ...ET 41820 R3...