System Preparation and Use 73
Using the Mist Coolant System
The Mist Coolant System has been designed to be used with
Gerber Cool coolant. Using other types of fluids may damage the
system.
Note: Gerber Cool should not be diluted prior to use.
CAUTION: DO NOT use toxic or volatile liquids.
The adjustable drip rate allows for a wide range of mist "wetness"
and cooling capability. The evaporation of the mist provides the
desired cooling effect and minimizes heat build-up of the
remaining lubricant as well.
1. Turn on the compressor and set the air pressure at 20-40 psi
as indicated on the mist coolant air pressure gage. To
increase
air pressure, turn the air pressure regulator
clockwise
. To
decrease
air pressure, turn the air pressure
regulator
counterclockwise.
2. Remove the brass filler plug using a flat head screwdriver and
fill the reservoir with Gerber Cool coolant. The reservoir
should remain full to assure proper lubrication. Add coolant
periodically to maintain the level.
3. Adjust the coolant nozzle so that it is directed at the point of
cutting.
CAUTION: Keep the nozzle at a safe distance to avoid
damaging it with the cutter.
4. Open the shut off valve near the nozzle coupling mounting
block. When open, the handle is aligned vertically with the
coolant tubing.