Operating Principles 15
Restoring Power
The emergency power switches turn off all power to the router.
Restore power by turning on the main power switch specific to
each router.
The router table emergency power switches on the Router 600
cannot be used to turn the router power on.
Router Motor Power Switch
The router motor power switch turns the motor on and off. The
router motor has a thumb switch on the top labeled ON and OFF.
CAUTION: The router motor switch should be off until the job
is ready to begin. DO NOT turn the router motor on when pen
plotting or scribing.
The router motor must be OFF during vacuum shroud
installation, tool changing, Z Axis initialization, or when
performing any other functions around the cutter.
When the job is ready to begin, turn ON the router motor power
switch.
Press the START key to start the job.
Note: There is a delay before the tool begins cutting. This delay
gives the router motor time to come up to full speed before cutting
begins, and the operator time to stop the job if the router motor is
not ON.