SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual
Last Updated August 2018
11
Warning
: When using multiple power supplies it is important to ensure that all ground connections
(V-) are connected between all power supplies and that no power connections (V+) are connected
between any power supplies.
The auxiliary outputs (S- S+) of the Controller can be used to supply other equipment. Note that there is no
onboard regulation or isolation for these outputs - they are a fused feed-through from the N+ N- input
terminals. When using these outputs to supply other devices, be sure not to exceed the rating of the internal
fuses as outlined in the Technical Specifications (see page 37).
Power over Ethernet (PoE)
PoE models only
Power can be supplied to the Controller by a PoE Router connected to the Ethernet terminal.
There are two types of PoE Routers available:
Low Power Type 1 (PoE) IEEE 802.3af, 12.95W Deliverable
High Power Type 2 (PoE+) IEEE 802.3at, 25.5W Deliverable
When using a PoE Router as the power source to the controller, the N+ and N- terminals become the network
outputs that can be used for powering the module network. The auxiliary outputs (S- S+) should be used for
powering readers and auxiliary loads such as locks.
The use of a High Power Type 2 (PoE+) Router is necessary when the Controller is required to supply a
combined auxiliary load of more than 600mA.
Controller
SB SA S- S+
Z2 V- Z1 NC C NO
RS 485 NETWORK 12 VDC OUT
ZONE 2
ZONE 1
RELAY 1
ETHERNET
N+ N- NA NB
12VDC IN/OUT RS 485 NETWORK
B- B+
BATTERY
When using a PoE Router as power source for the Controller, the rating for the auxiliary outputs (S-
S+) will be different to those when the Controller is being powered by an Genetec Power Supply or a
12V DC supply. Please refer to the values outlined in the Technical Specifications (see page 37) for
more details.