Technical Specifications
The following specifications are important and vital to the correct operation of this product. Failure to adhere to
the specifications will result in any warranty or guarantee that was provided becoming null and void.
Single Door Controller
Single Door Controller with POE
Operating Voltage
11-14V DC
Operating Current
120mA (typical)
DC Output
10.45-13.85VDC 0.7A (typical)
electronic shutdown at 1.1A
13VDC +/- 0.5 0.7A (typical)
electronic shutdown at 1.1A
Total Combined Current
*
0.82A (Max)
0.6A total at outputs, inclusive of
battery charging (PoE) / 1A total at
outputs, plus battery charging (PoE+)
Battery Charging
-
300mA (typical)
Battery Low
-
11.2VDC
Battery Restore
-
12.5VDC
Electronic Disconnection
9.0VDC
Communication (Ethernet)
10/100Mbps Ethernet communication link
Communication (RS-485)
2 RS-485 communication interface ports - 1 for module communications, 1 for
reader communications
Readers
1 RS-485 enabled reader port allowing the connection of up to 2 RS-485
capable readers providing entry/exit control for a single door
Inputs
2 high security monitored inputs
Relay Outputs
1 FORM C Relay - 7A N.O/N.C. at 30 VAC/DC resistive/inductive
Operating Temperature
UL/ULc 0˚ to 49˚C (32˚ to 120˚F) : EU EN -10˚ to 55˚C (14˚ to 131˚F)
Storage Temperature
-10˚- 85˚C (14˚ - 185˚F)
Humidity
0%-93% non-condensing, indoor use only (relative humidity)
Dimensions (L x W x H)
78 x 90 x 60mm (3.07 x 3.54 x 2.36")
Weight
167g (5.89oz)
205g (7.23oz)
*
The Total Combined Current refers to the current that will be drawn from the external power supply to supply
the Controller
and
any devices connected to the Controller's outputs. The Auxiliary outputs and Bell output are
directly connected via electronic fuses to the N+ N- input terminals, and the maximum current is governed by
the trip level of these fuses.
The size of conductor used for the supply of power to the unit should be adequate to prevent voltage drop at
the terminals of no more than 5% of the rated supply voltage.