TS4000
67
9.5 Specifications
Table 37: System Specifications
Specification
Description
Sensor Type
Electrochemical cell
Typical Life (Electrochemical Cell)
2 to 3 years under normal conditions
Warranty
- Two years for the Base Unit and Interface Module
- One year for the electrochemical cell
Malfunctions Monitored
- Calibration Errors
- Data Memory Errors
Measuring Ranges
- Ammonia (NH
3
): 0-50 ppm, 0-100 ppm
- Carbon Monoxide (CO): 0-100 ppm, 0-500 ppm
- Chlorine (Cl
2
): 0-10 ppm, 0-20 ppm
- Chlorine Dioxide (ClO
2
): 0-3 ppm
- Hydrogen Chloride (HCl): 0-20 ppm
- Nitric Oxide (NO): 0-100 ppm
- Nitrogen Dioxide (NO
2
): 0-20 ppm
- Oxygen (O
2
): 0-25% by volume
- Ozone (O
3
): 0-1 ppm
- Sulfur Dioxide (SO
2
): 0-20 ppm
Response Time
(100% FS Gas Applied)
- Cl
2
and ClO
2
: T90 < 60 sec
- CO and NO
2
: T90 < 30 sec
- HCl: T90 < 100 sec
- NH
3
and O
3
: T90 < 90 sec
- NO and SO
2
: T90 < 10 sec
- O
2
: T90 < 15 sec
Repeatability
± 5% FS or ± 2 ppm, whichever is greater
Zero Drift
< 5% per year
Approvals
CSA Certificate # 6114915
Table 38: Mechanical Specifications – Base Unit
Specification
Description
Length
6.6 inches (168mm)
Height
3.3 inches (84mm)
Width
4.4 inches (112mm)
Weight
5.5 pounds (2.5kg)
Mounting Holes
4.9 inches (124mm) center to center
Table 39: Mechanical Specifications - Interface Module
Specification
Description
Length
6.6 inches (168mm)
Diameter
1.75 inches (44mm)
Weight
1.0 pounds (0.45kg)
Mounting
¾
inch NPT
Housing
Anodized Aluminum