![background image](http://html1.mh-extra.com/html/general-datacomm/uas-7000/uas-7000_operation_2210296090.webp)
5-10
UAS 7626 DIU
GDC 087R706-000-02
2.
Select the SCM by typing its slot number and pressing the Enter key.
The SCM responds by displaying the Main SCM Menu.
3.
Type 8 and press the Enter key to select Backplane Control.
The SCM responds by displaying the Backplane Control menu.
4.
Type 3 and press the Enter key to select Service States.
The SCM responds by displaying the Current Service States screen, shown in Figure 5-10.
5.
Type the slot number that corresponds to the unit you’re working with and press the Enter
key.
The SCM responds by displaying
SLOT 5 UAS7626 DESIRED SERVICE STATE
[G] Go To -> Service States
[1] Line 1: Request Service State Up
If the current state of the unit were Up, selection 1 would read
Request Service State
Down
.
6.
Type 1 and press the Enter key.
The SCM responds by displaying a message that it is polling the shelf, and then returns to
the Current Service States screen. If the operation succeeded the new state is displayed for
the unit.
If the state is still Down after a command to go into service, it indicates the unit is not
configured correctly to go into service.
7.
Exit from the SCM card terminal interface functions by typing 0 and pressing the Enter key
at each screen until the Shelf Inventory screen is displayed.
Figure 5-10
SCM Current Service States Screen
CURRENT SERVICE STATES
--- Line Number ---
Slot Card 1 2 3 4
[1] SCM Up
[2] MP7001 Down
[3] UAS7626 Down
[4] UAS7626 Down
[5] UAS7626 Down
[6] UAS7626 Down
[7] MP7001 Up
[8] UAS7626 Up
[9] UAS7626 Up
[10] UAS7626 Up
[11] UAS7626 Up
[12]
[13]
[14]
[15]
[16]
[0] Go To -> Backplane Control [A] All Up [D] All Down
Enter 0, A, D or Slot Number: