2-6
UAS 7001 NIU
GDC 087R706-000-02
Table 2-1
Unit Configuration Option Settings (Continued)
The Unit Configuration procedure involves the following steps:
1.
From the Configuration menu, select the Unit Configuration screen by typing 1 and press-
ing the Enter key.
2.
Type the selection number of an option you intend to change and press the Enter key. High-
lighting appears on the current setting field for the corresponding option.
3.
Use the arrow keys to toggle the highlighted field through its potential settings.
4.
When the field displays the desired setting, press the Enter key. The highlighting disap-
pears and the field displays the new setting
5.
Repeat steps 2 through 4 for each option you need to change.
6.
To put the configuration changes you’ve made into effect, type S (Save) and press the Enter
key. You may use either upper or lower case for letter responses.
In response, the screen prompts for confirmation:
*WARNING - SAVING DISRUPTS COMMUNICATIONS Continue? [ ] Y(es), N(o)
7.
Continue the save process by typing
Y
and pressing the Enter key, or abort the save by typ-
ing
N
and pressing the Enter key.
If you continue the save, the word
SAVING
is displayed at the bottom of the screen. When
it disappears the save is complete and the new settings are in effect.
8.
When you’re done with Unit Configuration, you may either return to the Configuration
Menu screen by pressing the Enter key – identified as
CR
(Carriage Return) in the screen
prompt – or return to the Main Menu by typing
0
and pressing the Enter key.
If you start to leave the Unit Configuration screen while there are unsaved changes, the screen
displays
*WARNING - EXITING WITHOUT SAVING CHANGES Continue? [ ] Y(es), N(o)
You can type
N
and press the Enter key to keep the Unit Configuration screen on display while
you perform a save, or you can type
Y
and press the Enter key to finish exiting. Unsaved changes
are lost if you exit without performing a save.
Option
Potential Settings
[11] AIS Loopdown
(Seconds):
Inhibit; no loopback termination resulting from Alarm Indication Signal
(AIS) (Default)
05 – 60; number of seconds of AIS that causes termination of loopback test
[12] Line Buildout Control:
Valid only when Network
Interface Type is DS1
Manual (Default)
Auto
[CR]Return to Previous
Menu:
Returns you to the UAS 7001 Configuration menu screen
[S] Save