2-14
UAS 7001 NIU
GDC 087R706-000-02
The SCM responds by displaying
SLOT 2 MP7001 DESIRED SERVICE STATE
[G] Go To -> Service States
[1] Line 1: Request Service State Up
If the current state of the unit were Up, selection 1 would read
Request Service State
Down
.
6.
Type 1 and press the Enter key.
The SCM responds by displaying a message that it is polling the shelf, and then returns to
the Current Service States screen. If the operation succeeded the new state is displayed for
the unit.
If the state is still Down after a command to go into service, it indicates the unit is not
configured correctly to go into service. The critical options in this regard are Transmit
Clock Source in Unit Configuration and Shelf Timing Generator in System Configuration;
the unit cannot go into service unless those options are set correctly.
7.
Exit from the SCM card terminal interface functions by typing G and pressing the Enter
key at each screen until the Shelf Inventory screen is displayed.
Figure 2-8
SCM Current Service States Screen
CURRENT SERVICE STATES
--- Line Number ---
Slot Card 1 2 3 4
[1] SCM Up
[2] MP7001 Down
[3] UAS7616 Down
[4] UAS7616 Down
[5] UAS7616 Down
[6] UAS7616 Down
[7] MP7001 Up
[8] UAS7616 Up
[9] UAS7616 Up
[10] UAS7616 Up
[11] UAS7616 Up
[12]
[13]
[14]
[15]
[16]
[G] Go To -> Backplane Control [A] All Up [D] All Down
Enter G, A, D or Slot Number: