4-4
UAS 7616 DIU
GDC 087R706-000-02
Figure 4-3
Example of a Completed Configuration Worksheet – UAS 7000 with 7001 NIU
4.
Fill in the Data Rate column with the values that are to be established in DIU Unit Config-
uration. There are five possible combinations of Data Rate settings for the two channels that
make up a loop:
A: 128 kbps & B: Disable
A: 64 kbps & B: 64 kbps
A: 64 kbps & B: Disable
A: Disable & B: 64 kbps
A: Disable & B: Disable.
Slot
Device
Highway
Data Rate
DS0
5
UAS 7001 NIU (T1; DS0s 1 – 24)
2
NA
NA
UAS 7616 DIU –
Loop 1 – Channel A
64 kbps
10
Loop 1 – Channel B
64 kbps
12
6
Loop 2 – Channel A
64 kbps
14
Loop 2 – Channel B
64 kbps
16
Loop 3 – Channel A
64 kbps
18
Loop 3 – Channel B
64 kbps
20
UAS 7616 DIU –
Loop 1 – Channel A
128 kbps
1
7
Loop 1 – Channel B
Disable
2
Loop 2 – Channel A
128 kbps
4
Loop 2 – Channel B
Disable
5
Loop 3 – Channel A
128 kbps
7
Loop 3 – Channel B
Disable
8
UAS 7616 DIU –
Loop 1 – Channel A
64 kbps
3
Loop 1 – Channel B
Disable
NA
8
Loop 2 – Channel A
Disable
NA
Loop 2 – Channel B
64 kbps
6
Loop 3 – Channel A
Disable
NA
Loop 3 – Channel B
Disable
NA
UAS 7616 DIU –
Loop 1 – Channel A
128 kbps
21
12
Loop 1 – Channel B
Disable
22
Loop 2 – Channel A
64 kbps
11
Loop 2 – Channel B
64 kbps
17
Loop 3 – Channel A
128 kbps
23
Loop 3 – Channel B
Disable
24