5.4 Operation of the inverter on the control panel
On Monoblock vacuum units, the inverter controls operation of the suction turbine.
A transducer that measures operating suction pressure is connected to the inverter. Using the signals
received, the inverter maintains the pre-set operating parameters constant, increasing or reducing the
rotation frequency of the turbine as the conditions of use vary or according to the number of suction hoses
connected.
All parameters are optimized by the manufacturer and The programmed depression value is at -160mBar.