28
5.10 List of favourite parameters
The parameters in the favourites are divided into two groups:
●
User customisation parameters:
All the parameters highlighted in grey in the table belong to this list. They can be changed by the end user
without having to enter a password.
●
Central configuration parameters:
The remaining parameters (not highlighted in grey) are password-protected and need to be enabled for
modification. To change these parameters, enter
the password “
480”
using parameter
96.02.
After making
the change, enter password “
14
” using parameter
96.02
to lock the parameters again.
Parameter
Description
Default value
34_12
Timer 1
start time
08:00:00 PM
40_21
Internal Set Point
-160mbar
Lowest setting value -100mbar
Highest setting value -200mbar
31_04
Event type External Event 2
“Check Container”
“Check Container”
Warning
(the inverter will trip the alarm but the
vacuum system will continue to operate)
By setting Fault in case of alarm the vacuum system
will be stopped
31_10
Event type External Event 5
“Check Filter”
“Check Filter”
Warning
(the inverter will trip the alarm but the
vacuum system will continue to operate)
By setting Fault in case of alarm the vacuum system
will be stopped
47_04
Data Memory 4 real32
“Switch
-off frequency for wireless
systems”
Varies according to the vacuum system model
47_11
Data Memory 1 int32
“Switch
-
off delay for wireless systems”
30 sec.
47_12
Data Memory 2 int32
“Switch
-
off delay for Standard systems”
5 sec.
47_13
Data Memory 3 int32
“Check Container”
1000
(set 1000 for a trip time at 100 hours)
47_14
Data Memory 4 int32
“Check filter”
3000 for a system without self-cleaning
5000 for a system with self-cleaning
(set 2000 for a
trip time at 200 hours)
47_24
Data Memory 4 int16
“Operating Mode”
See
“OPERATING PRINCIPLE DEFINITION”
table at
section 5.9
96_01
Language
Italian
(unless customised otherwise)
96_02
Password
480
(password to unlock all favourite parameters)