Use and Maintenance Manual
MONOBLOCK Vacuum Unit
>>> Installation
18
4.2 Installation of the MONOBLOCK vacuum unit
–
1 and 2 operators
The MONOBLOCK vacuum unit has been designed for easy and convenient installation.
The vacuum unit must be positioned respecting the clearance distances indicated in
Figure 5.
The central
can be placed close to a wall on its right side, While on its left side there is a minimum distance of 30 cm
(advisable 50 cm) required, on the back the encumbrance e is shown in the figure. In these conditions of
installation the vacuum inlet is at approximately 70 cm, while the exhaust is at 171,5 cm from the ground
(see figure 5)
The MONOBLOCK vacuum unit must now be connected to the suction pipes of the system and to the air
expulsion pipe, using the rubber hoses with metallic fixing clamps provided.
IMPORTANT
●
Maximum distance from the Monoblock vacuum unit to the most distant suction
point 50 metres.
●
For the air expulsion pipe, the first 7 metres must consist in Ø63 mm pipes. After the
first seven metres, pipe diameter must be increased
●
Important: connect the muffler in metal to the exhaust pipe to reduce the noise of
the air in exhaust
Figure 5