30
The replacement procedure for the dust collection bag is as
follows:
●
Unhook the lower module of the separator by raising
the bin handle.
●
Extract the lower module of the separator by allowing
it to slide on its wheels with the assistance of the specific
handle.
●
Extract the dust collection bag and replace it with a
new one.
●
Fold the edges of the bag towards the exterior.
●
Hook up the dust container again to the separator. If it
is necessary to move the dust container away from the
separator to empty the dust collection bag, the vacuum tube
that keeps the bag in the correct position must be unscrewed.
6.3 Replacement of the filter cartridge (filter)
The filter cartridge must be checked and, if necessary, replaced when a progressive reduction of the suction
power of the system is noted.
Replacement is always necessary after two years of use.
Before proceeding with replacement operations, a protective mask and gloves must be
put on. Use only original spare bags supplied by General D’Aspirazione.
Failure to use these items of personal protection equipment may expose the operator to
the risk of inhalation of dust that is harmful to health, or of the contact of allergenic
substances with the skin.
Before proceeding with replacement operations, the power supply cable must be
disconnected. Failure to comply with this instruction may expose the operator to the risk
of accidental system starting.
While the dust container is being hooked up, there is the risk of cutting injuries to the
fingers.
After completing any kind of maintenance operation, remember the suction unit must
not be restarted without first having inserted the filter cartridge inside the separator.