![Geko Stromerzeuger 2801 E-A/SHBA Operating Manual Download Page 68](http://html1.mh-extra.com/html/geko/stromerzeuger-2801-e-a-shba/stromerzeuger-2801-e-a-shba_operating-manual_2206054068.webp)
Page 26
O
per
ation of the p
ow
er gener
at
or
use special additives.
The ambient temperatures determine the proper oil viscosity for the engine. Use the diagram to select
the best viscosity for the expected temperature range.
A
SAE 30
- Under 4°C (40°F), using SAE 30 makes it difficult to start the engine.
B
10W-30
- Using the 10W-30 above 80°F (27°C) can lead to increased oil consumption. Check
the oil level more frequently.
C
Synthetic oil 5W-30
D
5W-30
5.4.
Preparations for initial commissioning
NOTE
The power generator is delivered without engine oil. Never start the engine without engine oil. Damage
caused by operating the engine without oil cannot be repaired and is not covered by the manufacturer's
warranty.
We recommend that the oil level is checked at least twice a day during the running-in phase (approx. 200
operating hours). After the running-in phase, it is sufficient to check it once a day.
•
Fill the engine with oil.
For this, refer to the operating manual of the engine manufacturer.
•
Check the oil level.
This procedure is described in Chapter “5.5.2. Checking the oil level in the engine” on page
27.
•
Fill with fuel.
This procedure is described in Chapter “5.5.4. Filling fuel” on page 28.
•
Start the power generator.
This procedure is described in Chapter “5.6.1. Starting” on page 29.
•
Perform a 10-minute test run.
•
Do not operate the power generator without load.
Summary of Contents for Stromerzeuger 2801 E-A/SHBA
Page 2: ......
Page 22: ...Seite 20 Ihr Stromerzeuger im Detail 4 IHR STROMERZEUGER IM DETAIL 4 1 Abmessungen...
Page 42: ......
Page 62: ...Page 20 Your power generator in detail 4 YOUR POWER GENERATOR IN DETAIL 4 1 Dimensions...
Page 81: ......
Page 82: ......
Page 83: ......