48
RS-232 / TELNET COMMANDS
#set_serial_params Command
The #set_serial_params command sets the serial port parameters.
Syntax
y
:
#set_serial_params param1 param2 param3 param4 param5 param6
Parameters:
param1
Word length
[5
-
8]
param2
Stop
bits
[1
-
2]
s
param3
Parity
Parity
Meaning
n
None
e
Even
o
Odd
m
Mark
s
Space
param4
Baud rate
[9600 - 115200]
param5
Line delay (ms)
[0
-
10000]
Example:
p
#set_serial_params 1 8 1 N 9600 0
Default:
Data Bits: 8
Stop Bits: 1
Parity: None
Baud Rate: 19200