Water Quality
Water Chemistry is very important for the best performance of your UV
system. The following levels are recommended for installation:
Water Quality and Minerals
Level
Iron
<0.3 ppm (0.3 mg/L)
Hardness*
<7 gpg (120 mg/L)
Turbidity
<1 NTU
Manganese
<0.05 ppm (0.05 mg/L)
Tannins
<0.1 ppm (0.1 mg/L)
UV Transmittance
<75% (call factory for recommendations on applications
where UVT <75%)
If your water chemistry contains higher levels of those mentioned above,
proper pre-treatment is highly recommended to correct these water
problems prior to the installation of your UV disinfection system. These
water quality parameters can be tested by your local dealer, or by most
private analytical laboratories. Proper pre-treatment is essential for the UV
disinfection system to operate as intended.
Safety Instructions
To prevent injuries and ensure proper operation of the System,
please read and carefully follow these safety instructions. Please
save them for future reference:
WARNING
Once the system is installed, carefully examine it before connecting
to power.
The system should be connected to a properly grounded dedicated
power outlet protected by a ground fault circuit interrupter (GFCI).
Do not connect other devices to the same power outlet. The system
should not be connected to an outlet controlled by a light switch.
Since the system will be operated in the immediate proximity of
water, please make sure that the ballast and the lamp connector are
kept dry at all times. This will prevent electric shock and other
potential incidents related to the exposure of electrical equipment
to water.