Step 5.Remove the open-ended cap.
Step 7.Clean the quartz sleeve with
a cloth soaked in CLR, Lime away,
vinegar or any other mild acid.
Rinse the sleeve with water. Be sure
to remove all traces of the cleaning
liquid from the sleeve before it is
reinstalled.
Step 8.Reinstall the quartz sleeve
and the UV lamp into the chamber
following the installation
instructions.
NOTE: Very carefully remove the silicone stopper from the open
end of the quartz sleeve
After replacing the quartz sleeve (or the UV lamp), perform the disinfection
procedure, detailed in the disinfection procedure section of this manual.In case
the sleeve can no longer be cleaned completely, is scratched or cracked, replace
it with a new one.
Step 6.Remove the quartz sleeve
from the chamber.
12