Electrical Connections and Commissioning
Adjusting the Position Detecting Devices
34
Adjusting the Position Detecting Devices
The control top and lantern sensors are adjusted at the factory. During transportation or
installation these settings may alter and re-adjustment may be necessary (see operating
instructions Control top T.VIS M-15 or T.VIS A-15).
The standard adjustment procedure for control tops T.VIS A-15,
T.VIS M-15 as well as the lantern sensor are as follows:
WARNING
The following description is a summary of the basic adjustment steps and is not
intended as a substitute for the official operating instructions. The operating
instructions should always be consulted for comprehensive operation and safety
instructions.
Adjusting Control top T.VIS A-15
Control top T.VIS A-15 with 2 buttons
CAUTION
Danger if media are present in the valve when this is actuated!
They can escape or mix in the pipelines.
Make sure that no media are inside the valve.
Carry out the following steps:
1.
Connect the control air to the control top T.VIS A-15 (port P).
2.
Power up the control top by connecting the supply to the M12 pin connector.
Operating Instructions · VARIVENT
®