31
Installation
Pneumatic Connections
10.
Assemble the valve and depressurize the actuator.
The valve disk is lowered.
Done
NOTE
When assembling the valve always replace the housing O-rings to ensure that the valve
is tight.
Pneumatic Connections
Air requirement
Establishing the hose connection
To ensure reliable operation, the compressed air hoses must be cut exactly square.
Tools required:
A hose cutter.
Carry out the following steps:
1.
Shut off the compressed air supply.
2.
Use the hose cutter to cut the pneumatic hoses square.
3.
Push the air hose into the air connector on the control top.
4.
Re-open the compressed air supply.
Done
Size Type
Air requirement
(dm
3
n
/stroke)
dm
3
n
at 1.01325 bar
at 0°C as per DIN 1343
for
Total stroke
Air requirement
(dm
3
n
/stroke)
dm
3
n
at 1.01325 bar
at 0°C as per DIN 1343.
for Lifting
Stroke of valve disk
(lower disk)
Air requirement
(dm
3
n
/stroke)
dm
3
n
at 1.01325 bar
at 0°C as per DIN 1343
for Lifting
Stroke of double disk
(upper disk)
4"
SN6Z/ELMN6 5.60
2.25
0.30
6"
EH6Z/ELMN6 4.45
2.25
0.30