Maintenance
Disassembling
60
Operating Instructions · VARIVENT
®
Mixproof Valve M-C/2.0
Edition 2018-10-04
2.
Insert pin punch into the bore (16.1) and unscrew double valve disk (16).
3.
Withdraw sealing disk (3) with rod guide ring (2), O-ring (5), sealing ring (1) from the
lantern (9).
Done
Dismantling the Lifting Actuator
It is not necessary, to change the O-rings in the lifting actuator at every service.