ONE 7TS – Operation and use
4) Press the start button. If the electrical panel is supplied by
GEA Niro Soavi S.p.A.
this operation will
will enable the machine to be started according to the correct sequence, depending on the type of ma-
chine and of the optional equipment:
- opening solenoid valves for utilities (optional);
- starting main motor.
If the electrical panel is supplied by the customer, the correct operating sequence will be provided (See
TECHNICAL SPECIFICATIONS enclosed in chapter 11 of this manual), and this sequence should be ob-
served scrupulously.
6.3.3 Operation and adjustment
For a few minutes after the machine is started do not increase homogenizing pressure and check regular
operation and, in particular, the value of feed pressure and its stability within the limits indicated in the
TECHNICAL SPECIFICATIONS enclosed in chapter 11 of this manual.
You can now use the controls to set the homogenizing pressure to the required value.
To find out whether the system includes the second homogenization stage see the TECHNICAL
SPECIFICATIONS enclosed in chapter 11 of this manual.
6.3.3.1 Adjustment of homogenization pressure - 1 stage
This type of adjustment uses a servosystem which by means of a pneumatic cylinder acts on the position of
the homogenizing valve to determine homogenization pressure.
On the front panel of the machine (see figure 6-4 below), there is a pneumatic switch (A) and a pressure re-
ducer (B).
The adjustment operations are:
•
check that the pressure reducer (B) is completely loosened
•
pull the pneumatic switch to the ON position;
•
rotate the reducer to obtain the required homogenization pressure; this value can be checked on the
pressure gauge located on the head.
ATTENTION:
Slowly rotate the pressure regulator and check that the homogenization pressure is actually increas-
ing up to the operating value.
ATTENTION:
Check the increase of air pressure on the pneumatic head on the pressure gauge installed on the
control panel; this makes it possible to verify the slow increase of homogenization pressure. It is
also possible to use the air pressure gauge as a reference if the pressure gauge on the head is not
working correctly.
Once the homogenization pressure has been set to the required value you can block the reducer knob (B) by
pressing it.
pag 6.9
Il presente manuale è di proprietà
GEA Niro Soavi S.p.A.
ogni riproduzione, anche parziale, è vietata.
Summary of Contents for ONE 11TS
Page 2: ...GEA Niro Soavi S p A COVER02 DOC REV DESCRIPTION DATE SIGN 0 1 EDITION 05 07 2011 ANC ...
Page 235: ......
Page 245: ......
Page 247: ......
Page 255: ......
Page 263: ......
Page 264: ......
Page 265: ......
Page 266: ......
Page 267: ......
Page 268: ......
Page 269: ......
Page 270: ......
Page 271: ......
Page 272: ......
Page 273: ......
Page 274: ......
Page 275: ......
Page 276: ......
Page 277: ......
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ......
Page 282: ......
Page 283: ......
Page 284: ......
Page 285: ......