Handling and assembly
Axle assembly
2018-9015-001
09-2016
5.5.4
Translucent hose assembly
This step is not required for spreader equipped with oil on both sides of
suspension cylinder.
6
3
5
4
1
2
● Remove air valve from the cylinder opening (2);
● Apply Teflon tape on the straight adapter (1) threads;
● Screw the straight adapter (1) on the opening (2);
● Fit the translucent hose (3) on the straight adapter (1) and secure it using
a collar (4);
● Pour grade MV 22 HYDREX
TM
hydraulic fluid (5) in the translucent hose (3)
through the other end of the hose;
● Insert the end of the translucent hose (3) in the spreader frame (6);
● Repeat these steps for each cylinder.