Troubleshooting
Troubleshooting possible faults
2018-9015-001
09-2016
8.3
Troubleshooting possible faults
Spreading
Symptom
Possible cause
Solution
The spreader does not
spread properly or not at
all.
The liquid manure is too
thick.
Check consistency. Refer
to section Appendix -
Consistency test.
The directional valve is not
in the proper position.
Set the directional valve in
spreading position.
The self-loading inner valve
cylinder is not in the proper
position.
Set inner valve cylinder in
spreading position.
Foreign material in the
directional valve.
Contact your dealer.
Obstruction in the
discharge pipe.
Contact your dealer.
Obstruction in the impeller
output.
Contact your dealer.
The PTO is defective.
Refer to the manufacturer's
recommendations.
Worn out impeller or
housing.
Contact your dealer.
Liquid manure keeps
discharging from the tool
bar while the impeller is
stopped.
Anti-siphon is not
positioned properly.
The anti-siphon must be
positioned upward, adjust if
necessary. Refer to section
Handling and assembly -
Anti-siphon assembly.