Air requirement for opening the actuators
Nominal width of
valve
Actuator
Reference stroke
Air Requirement
DN
OD
[mm]
[dm
3
N
]
DN 6
--
PA35 NC
2
0.03
DN 8
--
PA35 NC
2
0.03
DN 10
OD ½"
PA35 NC
2
0.03
DN 15
OD ¾"
PA35 NC
5
0.05
6.4.2
Establishing the Compressed Air Supply
A prerequisite for the reliable operation of the valve is that the compressed air
hoses are cut exactly square.
Tools required:
•
A hose cutter
Carry out the following steps:
1.
Depressurize the pneumatic connection at the place where you are working.
2.
Use the hose cutter to cut the pneumatic hoses square.
3.
Connect a hose to the valve.
®
The compressed air supply has been established.
Assembly and installation
Pneumatic connections
430BAL013317EN_1
11.03.2019
25
Summary of Contents for Aseptomag AMV