3.4.2
HOMOGENIZING PRESSURE ADJUSTMENT - 2 STAGES
To adjust the pressure, follow the same steps as for the single-stage machine.
In order to adjust the pressure, please read carefully what is written in
paragraph 3.4.1, and in specific all warnings.
The pressure to be applied by the second stage varies from about 1/10 to 1/5 of
the maximum homogenizing pressure, according to the product handled.
WARNING: The intended homogenizing pressure value must be set FIRST
on the second stage, THEN on the first stage to reach the total desired
pressure.
A different operating sequence may result in SERIOUS RISK because the
machine may inadvertently and suddenly reach higher pressure values
than those for which the machine is designed..
Adjustment operations consist of (see figure 3.4.1):
•
make sure the pneumatic regulator is completely backed off counterclockwise
•
set the 2nd stage pneumatic switch (A) to ON position;
•
rotate the 2nd stage reducer knob (B) until the desired homogenizing
pressure is obtained, by reading the reached value on the pressure gauge.
•
set the 1st stage pneumatic switch (C) to ON position;
•
rotate the 1st stage reducer knob (D) until the desired homogenizing
pressure is obtained, by reading the reached value on the pressure gauge.
WARNING: To allow a slow, gradual pressure increase, the pneumatic
adjustment system has been designed to ensure a certain inertia.
Operate the pressure regulator slowly while checking the actual
homogenizing pressure increase until the operating value has been
reached.
ATTENTION: check the air pressure increase on the pneumatic adjuster
using the air pressure gauge located on the control panel; this allows a
slow rise of the pressure. It is also possible to use this air gauge as a
reference for the homogenizing pressure in case the main gauge on the
compression block is not working properly as a temporary solution to be
able to work with the machine.
Once the homogenizing pressure has been set to the desired value, block the
reducer knob (B and D) by pressing it.
If the set pressure is the one used normally during production, the
homogenizing pressure can be applied or released by operating ONLY the
pneumatic selector (A and C), with the reducer left on the adjustment position.
3C001E0C.DOC 3.4.3
Summary of Contents for ARIETE
Page 7: ......
Page 10: ......
Page 18: ...Niro Soavi S p A FIGURE 2 2 2 2C001E0C DOC 2 2 2 ...
Page 52: ...Niro Soavi S p A FIGURE 3 2 1 2 1 D A B C FIGURE 3 2 2 3C001E0C DOC 3 2 3 ...
Page 76: ...Niro Soavi S p A 3 9 SPECIAL FEATURES OF NON STANDARD MACHINES BLANK PAGE Ricerca Guasti 21 2 ...
Page 93: ...Niro Soavi S p A 4C042E0C DOC 4 4 8 FIGURE 4 4 3 FIGURE 4 4 3 ...
Page 109: ...Niro Soavi S p A FIGURE 4 6 1 4c063e0c doc 4 6 3 ...
Page 134: ...Niro Soavi S p A FIGURE 4 9 1 4c091e0c doc 4 9 4 ...
Page 155: ...Niro Soavi S p A 5C001E0C DOC 5 3 3 ...
Page 160: ......
Page 162: ......
Page 164: ......
Page 166: ......
Page 168: ......
Page 170: ......
Page 172: ......
Page 174: ......
Page 176: ......
Page 178: ......
Page 180: ......
Page 182: ......
Page 184: ......
Page 186: ......
Page 188: ......
Page 190: ......
Page 192: ......
Page 195: ......
Page 201: ......
Page 202: ......
Page 203: ......
Page 211: ......
Page 212: ......
Page 213: ......
Page 214: ......
Page 215: ......
Page 216: ......
Page 217: ......
Page 218: ......
Page 219: ......
Page 220: ......
Page 221: ......
Page 222: ......
Page 223: ......
Page 224: ......
Page 225: ......
Page 226: ......
Page 227: ......
Page 228: ......
Page 229: ......
Page 230: ......
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......
Page 236: ......
Page 237: ......
Page 238: ......
Page 239: ......
Page 240: ......
Page 241: ......
Page 242: ......
Page 243: ......
Page 244: ......
Page 245: ......
Page 246: ......
Page 247: ......
Page 248: ......
Page 249: ......
Page 250: ......
Page 254: ......
Page 255: ......
Page 264: ......
Page 265: ......
Page 266: ......
Page 270: ......
Page 272: ......
Page 330: ......
Page 331: ......
Page 332: ......
Page 390: ...VLT 5000 Series MG 51 A1 02 VLT is a registered Danfoss trade mark 56 ...
Page 429: ...VLT 5000 Series MG 51 A1 02 VLT is a registered Danfoss trade mark 95 Special functions ...
Page 542: ......
Page 543: ......
Page 544: ......
Page 546: ......
Page 547: ......
Page 548: ......
Page 549: ......
Page 550: ......
Page 551: ......
Page 554: ......
Page 555: ......
Page 556: ......