I/O Connector
Three 10-pin connectors (P16, 17, and 18) on the back panel provide the connections for the alarm inputs,
outputs, and other data lines. Connect the wires to the 3 terminating connectors provided with the SymDec 4.
See the table below for a description of the pinouts.
Note:
Do not attempt to wire accessories directly to the I/O connector.
Ethernet Port
The cable connection configuration for the ethernet port depends on your network configuration:
•
For a SymDec 4 that connects directly to a hub, use a straight through connection.
•
For a SymDec 4 that connects directly to a PC, use a cross-over connection.
Consult with your network administrator or IS professional for the specific type of configuration. See
Advanced Menu / Communications / Ethernet Settings
on page 70 for information about configuring the
Ethernet settings in the menu system
Table 4.
P16
P17
P18
Pin
Signal
Pin
Signal
Pin
Signal
1
Alarm Relay 1 N/Open
1
Alarm Input 3
1
Not used
2
Alarm Relay 1 Common
2
Alarm Input 4
2
Not used
3
Alarm Relay 2 N/Open
3
Alarm Reset 1
3
Not used
4
Alarm Relay 2 Common
4
Alarm Reset 2
4
Not used
5
Not used
5
Alarm Reset 3
5
Not used
6
Not used
6
Alarm Reset 4
6
Ground
7
Not used
7
Not used
7
Disk End Output
8
Not used
8
Not used
8
Ground
9
Alarm Input 1
9
Not used
9
Alarm Output
10
Alarm Input 2
10
Not used
10
Ground
Ethernet
10/100Base-T, auto sensing
Wire type
Cat 5
Connector type
RJ-45
Max cable length
328 feet/100 meters
Minimum cable length
6 feet/1.8 meters
Hub wiring configuration
Straight through
PC wiring configuration
Cross over