Appendix A: Connectors and Pinouts 84
A.7 PMC Site 2 Connectors (J21, J22, J23, J24)
The
PCI
Mezzanine
Card
(PMC)
carries
the
same
signals
as
the
PCI
standard;
however,
the
PMC
standard
uses
a
completely
different
form
factor.
through
are
the
pinouts
for
the
PMC
connectors
(J21,
J22,
J23
and
J24).
A.7.1 PMC Connector and Pinouts (J21)
Figure A-12 PMC Site 2 Connector and Pinouts (J21)
Table A-24 PMC Site 2 Connector Pinouts (J21)
PMC Connector (J21)
PMC Connector (J21)
Left Side
Right Side
Left Side
Right Side
Pin
Name
Pin
Name
Pin
Name
Pin
Name
1
JTAG.TCK
2
-12
33
FRAME#
34
GND
3
GND
4
INTA#
35
GND
36
IRDY#
5
INTB#
6
INTC#
37
DEVSEL#
38
+5 V
7
BMODE1#
8
+5 V
39
PCIXCAP
40
LOCK#
9
INTD#
10
NC
41
SDONE#
42
+3.3V
11
GND
12
NC
43
PAR
44
GND
13
CLK
14
GND
45
PMC VIO*
46
AD[15]
15
GND
16
GNT0#
47
AD[12]
48
AD[11]
17
REQ0#
18
+5 V
49
AD[9]
50
+5 V
19
PMC VIO*
20
AD[31]
51
GND
52
C/BE[0]#
21
AD[28]
22
AD[27]
53
AD[6]
54
AD[5]
23
AD[25]
24
GND
55
AD[4]
56
GND
25
GND
26
C/BE[3]#
57
PMC VIO*
58
AD[3]
27
AD[22]
28
AD[21]
59
AD[2]
60
AD[1]
29
AD[19]
30
+5 V
61
AD[0]
62
+5 V
31
PMC VIO*
32
AD[17]
63
GND
64
REQ64#
NOTE: *PMC VIO is determined by the location of the PMC keypin.