Installation and Setup 29
.
1.7 Installation of SBC622 into Chassis
The
SBC622
conforms
to
the
VPX
physical
specification
for
a
6U
board.
The
SBC622
can
be
configured
as
the
system
controller
or
as
a
peripheral
board.
It
can
be
plugged
directly
into
any
OpenVPX
chassis
conforming
to
a
backplane
profile
compatible
with
the
payload
profile
of
the
SBC622.
See
CAUTION
Do not install or remove the board while power is applied.
The
following
steps
describe
the
recommended
method
for
installation
and
powerup
of
the
SBC622:
1.
Make
sure
power
to
the
equipment
is
off.
2.
Connect
a
PMC
or
an
XMC
module
to
the
SBC622
(if
it
is
to
be
used)
prior
to
board
installation.
See
32.
Refer
to
the
Product
Manual
for
the
XMC/PMC
module
for
configuration
and
setup.
NOTE
Air flow as measured at the output side of the heatsink is to be greater than 450 LFM.
3.
Choose
chassis
slot.
If
the
SBC622
is
to
be
the
VPX
system
controller,
choose
the
appropriately
marked
VPX
slot.
The
SBC622
does
not
require
jumpers
for
enabling/disabling
the
system
controller
function.
4.
Insert
the
SBC622
into
a
VPX
chassis
system
controller
or
peripheral
slot.
a. While
ensuring
that
the
board
is
properly
aligned
and
oriented
in
the
supporting
board
guides,
slide
the
board
smoothly
forward
against
the
mating
connector.
b. Use
the
ejector
handles
(for
air
‐
cooled
options)
to
firmly
seat
the
board.
5.
Access
all
needed
peripherals
from
the
front
panel
or
the
rear
I/O.
Each
connector
is
clearly
labeled.
Detailed
pinouts
are
in
.
6.
Connect
a
keyboard
and
mouse
if
the
system
has
not
been
previously
configured.
7.
If
an
external
drive
module
is
installed,
the
BIOS
Boot
Setup
Menu
or
F7
first
boot
key
may
be
used
to
select
booting
from
the
drive.
If
applicable,
see
Appendix
B.
8.
Install
the
operating
system
according
to
the
manufacturer’s
instructions,
if
a
drive
module
is
present.