10
Installation Requirements.
INLET/OUTLET PLUMBING REQUIREMENTS
Always install either a single bypass valve
(provided),as shown in Figure 4, or, if desired, parts
for a 3 valve bypass system (not included) can be
purchased and assembled, as shown in Figure 5.
Bypass valves allow you to turn off water to the
softener for maintenance if needed, but still have
water in house pipes.
Pipe fittings must be 1/2” minimum.
Use:
&RSSHUSLSH
7KUHDGHGSLSH
3(;&URVVOLQNHG3RO\HWK\OHQHSLSH
&39&SODVWLFSLSH
2WKHUSLSHDSSURYHGIRUXVHZLWKSRWDEOHZDWHU
IMPORTANT:
Do not solder with plumbing
attached to installation adaptors and single
bypass valve. Soldering heat will damage the
adaptors and valve.
WARNING:
A copper or galvanized cold water pipe may be
used to ground electrical outlets in the home.
Failure to maintain this ground path may result
in an electric shock hazard. If the cold water pipe
is used to ground electric outlets, please refer to
Installing the Ground Wire
section before cutting
the pipe.
3-VALVE BYPASS SYSTEM
For soft water service:
Open the inlet and outlet
valves and close the bypass valve.
For bypass hard water:
Close the inlet and outlet
valves and open the bypass valve.
3 VALVE BYPASS
Bypass
Valve
Outlet
Valve
Inlet
Valve
From Water
Softener
To Water
Softener
Figure 5
SINGLE BYPASS VALVE
Pull out for “Service”
(Soft water)
Push in for
“Bypass”
Figure 4