Installation Instructions.
TURN OFF WATER SUPPLY
1. Close the main water supply valve, located near
the well pump or water meter.
2. Open all faucets to drain all water from house
pipes.
NOTE:
Be sure not to drain water from the water
heater, as damage to the water heater elements
could result.
INSTALL THE BRINE TANK OVERFlOW
ADAPTER
Install the brine tank overflow grommet and
adapter in the 13/16” diameter hole in the back of
the salt storage tank sidewall, (see Figure 9).
NOTE:
The brine tank overflow adapter accepts
either 1/2” or 3/8” I.D. hose
.
INSTALL THE BYPASS VALVE
NOTE:
For easier installation, remove the top
cover. Release 2 clips at rear of cover. Rotate
cover forward and lift up.
1. Visually check and remove any debris from the
water softener valve inlet and outlet ports, (see
Figure 7).
2. Make sure the turbine assembly spins freely in
the”out” port of the valve, (see Figure 8).
3. If not already done, put a light coating of
silicone grease (provided) on the single bypass
valve o-rings, (see Figure 7).
4. Push the single bypass valve into the softener
valve as far as it will go. Snap the two large
holding clips into place, from the top down, (see
Figure 7 and 10).
IMPORTANT:
Be sure the clips snap firmly into
place so the single bypass valve will not pull out.
MOVE THE WATER SOFTENER INTO PLACE
WARNING!
Excessive Weight Hazard
Use two or more people to move and install
water Softener Failure to do so can result
in back or other injury.
1. Move the water softener into the desired
location. Set it on a solid, level surface.
IMPORTANT:
Do not place shims directly under
the salt storage tank to level the softener. The
weight of the tank, when full of water and salt,
may cause the tank to fracture at the shim.
Salt
Cover
Brinewell
Cover
Brine
Tank
Stand
Tube
Brine
Valve
Assembly
Float Stem
Brinewell
Brine
Tubing
Brine Tank
Overflow
Adapter
Grommet
Hole
Nut - Ferrule
Nozzle Venturi
Assembly
Figure 9
SINGLE BYPASS VALVE
CORRECT ASSEMBLY
Outside diameter of
clip channel on single
bypass valve
If connecting to floor
level plumbing, install
the bypass valve turned
downward, as shown.
Clip
Outside diameter of
water softener valve
inlet & outlet
NOTE:
Be sure all 3 tabs of the clip go through the match-
ing holes on the water softener valve inlet or outlet, and
fully into the channel on the single bypass valve. Make sure
that the tabs are fully seated.
Figure 10
Note:
Unit is shown with top cover removed.