49
Steam Components
Steam Tube
Mist Nozzle
Nozzle Holder
Steam Elbow
Water Valve
Retainer
Mist Nozzle
The mist nozzle is located inside the dryer on the left
side of the rear bulkhead. The mist nozzle consists
RIDEUDVVRUL¿FHDQGD¿QH¿OWHUVFUHHQ,IWKHRUL¿FH
should become plugged or restricted, it should not
be cleaned. Replace a plugged or restricted misting
nozzle.
Nozzle Holder
Nozzle Holder Removal
1. Disconnect the steam tube from the water valve.
2. Remove the nozzle retainer by twisting slightly
counter-clockwise.
Water Valve
Operating Voltage: 120 VAC
Resistance
aNű
Water Valve Removal
1. Disconnect power and water from the unit.
2. Remove the control panel.
3. Remove the top panel.
4. Disconnect the water valve wire harness and the
water line.
5. Remove the 1/4 in. hex screw that holds the wa-
ter valve in place.
1/4" hex
6. Slide the water valve slightly left to remove.
See Control Panel Removal on page 20.
See Top Panel Removal on page 24.