41
Electric Heating System
Heater Assembly
Operating Voltage: 240 VAC
Resistance
ű+HDWHU
Wattage: 3000 Watts / Heater
The heater consists of an upper coil and a lower
coil. Normal heater cycling is controlled by the main
control board. The control board reads the inlet and
outlet thermistors to cycle the heaters. If a thermis-
tor fails, the heaters will be cycled by the inlet and
outlet thermostats. This may result in slightly less
HȻFLHQWRSHUDWLRQ
L2
Motor Centrifugal Switch
K4
Outlet Backup
Thermostat
L1
Intlet Backup
Thermostat
J2
Bottom Coil
Top Coil
K3
Main Control
Board
J3
J8
J5
Heater Removal
1. Disconnect water and power to the dryer.
2. Remove the control panel.
3. Remove the top panel.
Remove the front panel.
4. Remove the front control assembly bracket.
5. Remove the front drum support.
6. Remove the drum (see Drum Removal).
7. Disconnect the wire from the heater assembly.
8. Remove the two 1/4 in. hex screws that hold the
electric shield.
9. Remove the two 1/4 in. hex screws that hold the
heater assembly in place.
10. Remove the heater from the rear duct tab.
Heat Shield
Heater Bracket
High Limit Thermostat
Heater Assembly
Inlet Thermostat
High Limit Thermostat Location
Inlet Thermostat Location
See Heater Assembly Location on page 17.
See Control Panel Removal on page 20.
See Top Panel Removal on page 24.
See Front Panel Removal on page 24.
See Front Control Assembly Bracket Removal
on page 25.
See Front Drum Support Removal on page 34.