15
Error Codes
SSD Error Name
Error Set Condition
Error Clear Conditions
Error Response Action
000 No Error
No Errors
001 Inlet Thermistor
Short
Inlet Thermistor’s
count of low readings
exceeds 10.
Inlet Thermistor’s count
of good readings exceeds
10.
Run Heat Control Fallback
Algorithm.
002 Outlet Thermistor
Short
Outlet Thermistor’s
count of low readings
exceeds 10.
Outlet Thermistor’s count
of good readings exceeds
10.
Run Heat Control Fallback
Algorithm.
003 Inlet Thermistor
Open
Inlet Thermistor’s
count of high readings
exceeds 10.
Inlet Thermistor’s count
of good readings exceeds
10.
Run Heat Control
Fallback Algorithm.
004 Outlet Thermistor
Open
Outlet Thermistor’s
count of high readings
exceeds 10.
Outlet Thermistor’s count
of good readings exceeds
10.
Run Heat Control
Fallback Algorithm.
005 EEPROM Error
Bad CRC Detected
when reading a
page from EEPROM.
Error condition clears
when EEPROM checksum
is right.
006 Stuck Button
Button depressed for 5
minutes.
When the button is re-
leased.
Cleared when stuck but-
ton is released.
007 Miswire
L2/N are miswired.
Cleared when voltage
drops to Normal Levels.
L2 and N need to be re-
wired.
008 Door Switch Stuck 5 cycles are run and
the DOOR_LATCH_SIG-
NAL has not gone
open.
DOOR_LATCH_SIGNAL
goes to open.
009 Drum Motor
Centrifugal Switch does
not change within a
certain period of time
after the Drum Motor
relay has been turned
RQRURȺ
Error condition will not
clear until Main Control
board sees a change in
the centrifugal switch.
00d Door Signal Stuck
5 cycles are run and
the DOOR_STATE
signal in the hardware
Door Switch Detection
Circuit, has not gone
RSHQIRU¿YHF\FOHV
Error condition will not
clear until the Main Con-
trol Board sees the door
switch change.
Micro Blackout Recovery
to Run will not occur if this
error is set, and control
will go to pause.