45
:KHQWKHVDIHW\YDOYHRSHQVWKHPDLQFKDPEHU¿OOV
with gas, as shown below.
Safety Valve Open
:KHQWKHPDLQYDOYHRSHQVJDVÀRZVRXWRIWKH
PDLQFKDPEHUDQGRXWWKURXJKWKHRUL¿FHDVVKRZQ
below.
Electrical Operation
IGNITOR
(GLOWING RED)
DETECTOR
MAIN
SAFETY
BOOSTER
L1
N
Flame Detector Closed
When the igniter reaches ignition temperature (ap-
SUR[LPDWHO\VHFRQGVRUOHVVWKHÀDPHGHWHFWRU
opens. This causes the main coil to be in series with
the igniter, which causes the igniter to cool down.
+RZHYHUWKHÀDPHGHWHFWRULVKHOGRSHQE\UDGLDQW
KHDWIURPWKHJDVÀDPH7KHERRVWHUFRLOLVQRZLQ
series with the main coil, and is essentially inopera-
tive.
IGNITOR
(NOT GLOWING)
DETECTOR
MAIN
SAFETY
BOOSTER
L1
N
Flame Detector Open
Should a momentary power failure occur, the valve
ZLOOVKXWRȺDQGDQDWWHPSWWRUHVWDUWZLOOQRWRFFXU
XQWLOWKHÀDPHGHWHFWRUFRROVGRZQ
Gas Conversion
To convert the dryer from natural gas to LP gas,
refer to the conversion kit (Part #: WE25X10032).
To convert the dryer from LP gas to natural gas, refer
to the conversion kit (Part #: WE25X10033).
Gas Valve
Operating Voltage: 120 VAC
Booster Resistance
ű
Safety Resistance
ű
Main Resistance
ű
The gas valve and coils come as a complete assem-
bly, coils are not available as a separate part.
Gas Valve Removal
1. Disconnect power from the unit.
2.
6KXWRȺWKHJDVVXSSO\
See Gas Valve Location on page 44.