Window
Instillation in Window
26” Wide
●
Follow all instructions on pages
7-9 except steps 1 through 6 on
page 9.
●
Use foam
to fill any openings
between the sides of the cabinet
and the window stop molding.
Installation Other Than
Mounting
In order to install the appliance
with more of it projectin
g
into
the room, it will be necessary to
relocate the top retaining bar and
the bottom tie bar.
1. Check to make sure the cabinet’s
side louvers will not be blocked
when the unit is moved farther into
the room.
2. Remove the top retainer bar
cabinet side seals, and bottom tie
bar from the cabinet. Relocate them
for the desired projection into the
room.
3. Using the top retaining bar and
cabinet side seals as templates,
locate and drill five 7/32” mounting
holes in the top of the cabinet and
three on each cabinet side.
Top Retainer Bar
7/32”
Holes
, Cab[net
Tie Bar
4. Use sealing material (furnished)
Drain
A condensate drain is provided to
divert excess water when the air
conditioner is installed over a
doorway or sidewalk.
Caution: Do not drill a hole in
the base pan.
1. Pry the cap plug from the
condensate drain (located on the
underside of the base pan). Use a
3/8” pipe tap and fully thread the
condensate drain.
I
Cap
Condensate
J
2. Screw a 3/8” pipe fitting into the
condensate drain. The fitting should
protrude approximatel
y
above
the base pan when fully threaded
into the condensate drain.
Condensate Drain
Base Pan
Condensate Drain
3. If an open drain source is used
to dispose of condensate, plastic or
rubber tubing may be run directly
from the pipe fitting to the open
drain source. If a closed drain
source (internal
is used, a “P” trap must be
the 3/8” pipe fitting and the closed
drain source.
Pipe
To Closed
Fitting
Drain Source
~&
.
“P”
to fill the
in the cabinet top and
cabinet sides that became exposed
when the top retaining bar and
cabinet side seals were relocated.
5. Follow all instructions on pages
7 through 9.
10