Window Mounting

Window Requirements

2. -Cabinet in Window.

This air conditioner is factory-

1. Open the window and mark the

prepared for installation in standard

center of the window stool. Carefully

double-hung windows with

place the cabinet in the window and

● 

actual opening width of 

to 

● 

 vertical opening of 16”

minimum from bottom of sash

to stool.

 to 

min.

align the center mark on the bottom
tie bar with the center mark on the
window stool.

I

 Retainer Bar

Bottom Tie Bar 

For instillation in windows with
a minimum opening width of 

2. Close the window until it touches

see page 10.

behind the top retainer bar. Do not
close it so 

 that the sliders

Note: All supporting parts should

cannot move. (Do not release your

be secured to firm wood, masonry

grip on the cabinet until the lower

or 

window sash is in its 

 position.)

1. Remove the Chassis.

3. 

 the cabinet to the window

stool by driving 

 A screws

Slide the chassis out of the cabinet

through the 

 track into the

 

 the chassis forward

window stool.

 

while 

 the cabinet. Remove

I

the screen, if necessary, and

Type A Screw

replace it after installation.

Cabinet

Screen

4. Loosely attach the sill bracket
to the support bracket, using the
carriage bolt and flange nut.

 Bracket

 1

.

 

I

5. Using the 

 B machine screw

and flange nut, 

 the support

bracket to the cabinet track. Use
the track hole that aligns with the

bracket on the outer edge of the
window sill.

Attach the sill bracket to the
window sill using 

 A screws.

Tighten the carriage bolt and
flange nut.

Be sure the cabinet maintains its
outward pitch. This allows the air
conditioner to slant 

 downward

on the outside and prevents water
from entering the room.

 of

I

Cabin
Track

Support 

\

Carriage Bolt
and Flange Nut

8

Summary of Contents for AVD14

Page 1: ...pair Service 6 Care and Cleaning 5 Safety Instructions 2 Condenser Coils 5 User Maintenance Instructions 5 Control Settings 3 4 Warranty Back Cover Electrical Requirements 7 Energy Saving Tips 2 Extension Cords 7 Grille and Cabinet 5 Grounding 7 GEAmwer Center Installation Instructions 7 11 8fi 6262000 Model AVD14 GEAppIances ...

Page 2: ...stilled in accordance with the Instillation Instructions before it is used See grounding instructions on page 7 Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the receptacle Repair or replace immediately all electric service cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage al...

Page 3: ...conditioner is shut off wait at least two minutes before restarting it COOLER 09 llllll 1 10 7 6 e 4 1 50 4 0 3 1 3 Thermostat Control When you turn the Thermostat Control to the desired setting the Ventilation Control When this control is turned to the CLOSED position only the air thermostat will automatically control inside the room can be circulated the temperature of the indoor air and conditi...

Page 4: ...et on 9 or 10 and the Fan is set on low speed moisture may freeze on the coils and prevent the unit from cooling If this happens set the fan at high speed and the Thermostat Control to a lower number 3 Set the Ventilation Control at CLOSED For ni ttime operation During the cooler evening hours we recommend that you set the Selector Switch at LOW COOL for very quiet operation and the Thermostat Con...

Page 5: ... numbers easier to read I To remove the grille unscrew the attachment Gobs on each side of the grille Then grasp both sides of the grille and pull it forward and off To replace the grille lineup the tabs on the grille with the holes in the cabinet insert the attachment knobs and screw them finger tight Air Hlter The air filter behind the front grille should be washed at least evefi 30 days or as o...

Page 6: ...ycles on and off This is normal Fan runs continuously when Selector Switch is in Cool or Fan position This is normal Excess water may overflow in extremely hot and humid weather This is normal Air conditioner must be installed with the specified tilt to the outside for proper water disposal This is normal for a short period in areas with little humidity normal for a longer period in very humid are...

Page 7: ...o wall outlet cover OR REMOVE THE THIRD screw does not ground appliance GROUND PRONG OM unless cover screw is metal and THE POWER CORD not insulated and wall outlet is groundd through house wiring You hould have cir uit checked by a qualified electrician to make sure Use of adapter plug the outlet is properly grounded Because of potential safety When disconnecting the power hazards under certain c...

Page 8: ...metil window sash is in its final position 1 Remove the Chassis 3 Attich the cabinet to the window stool by driving pe A screws Slide the chassis out of the cabinet through the ca ine track into the by ullin the chassis forward window stool while bra cing the cabinet Remove I the screen if necessary and Type A Screw replace it after installation Cabinet Screen 4 Loosely attach the sill bracket to ...

Page 9: ...ing by required width Using a sharp knife driving upholsterers tacks through and insert the line cord into the mark the groove until the filler panel the holes in the filler panel flange notch in the cabinet Make sure the front of the chassis is flush with the becomes weak enough to break apart X Minus One Groove 3 16 Filler anel 3 Insert the cut edge of the filler panel into the cabinet side seal...

Page 10: ...aling material furnished Condemate Drain A condensate drain is provided to divert excess water when the air conditioner is installed over a doorway or sidewalk Caution Do not drill a hole in the base pan 1 Pry the cap plug from the condensate drain located on the underside of the base pan Use a 3 8 pipe tap and fully thread the condensate drain I Cap Plug k p Condensate Drain J 2 Screw a 3 8 pipe ...

Page 11: ...racing cabinet with one hand while pulling chassis out with other hand 3 Instill Cabinet in Wall 1 Remove and discard top retainer bar and cabinet side seals 2 Put cabinet in wall opening 3 Attach cabinet to wood frame w q 1 Long d Wood Screws a Drive 2 locally obtained 1 long wood screws through cabinet track into wood frame bottom II I II b Drive 11 locally obtained 1 long wood screws hrough hol...

Page 12: ...LECTRIC CUSTOMER CARE SERVICE WHAT IS N COVERED Service trips to teach you how to use the product Read your Use and Care material If you then have any questions about operating the product please contact your dealer or our Consumer Affairs office at the address below or call toll free GE Answer Cente 800 626 2000 consumer information service Improper installation If you have an installation proble...

Reviews: