background image

Care and 

USER 
INSTRUCTIONS

Turn air conditioner off and
remove plug from wall outlet
before cleaning.

Grille & Cabinet

Wipe front grille with a clean cloth
lightly dampened with mild liquid

 detergent. Wash cabinet

with mild soap or detergent and
lukewarm water.

 

These coils on the weather side
of the unit should be checked
periodically and cleaned if clogged
with dirt or soot from the atmosphere.
If extremely soiled, they may need
to be steam cleaned, a service
available through your GE service
outlet.

 Grille 

The front grille can be removed to
make the air filter accessible, allow

more thorough cleaning or make the
model and serial numbers easier to
read.

I

/-

To remove the grille, unscrew

 attachment 

 on each side of

the grille. Then grasp both sides of
the grille and pull it forward and off.

To replace the grille, lineup the
tabs on the grille with the holes in
the cabinet, insert the attachment
knobs and screw them finger tight.

Air 

The air filter behind the front 
should be washed at least 

 30

days or as often as it needs
cleaning.

To remove the filter, first remove
the front grille, then carefully
unhook the filter from the frame.

Vacuum the filter on the dusty side
to remove light dust. Wash the filter,

 side up, under 

 flowing

water to wash out accumulated dust
and lint. If the filter is very dirty,
use a mild household detergent in
the wash water. Let the filter dry
thoroughly before replacing it.

After cleaning the filter, put it
back into place and replace the
front grille.

5

Summary of Contents for AVD14

Page 1: ...pair Service 6 Care and Cleaning 5 Safety Instructions 2 Condenser Coils 5 User Maintenance Instructions 5 Control Settings 3 4 Warranty Back Cover Electrical Requirements 7 Energy Saving Tips 2 Extension Cords 7 Grille and Cabinet 5 Grounding 7 GEAmwer Center Installation Instructions 7 11 8fi 6262000 Model AVD14 GEAppIances ...

Page 2: ...stilled in accordance with the Instillation Instructions before it is used See grounding instructions on page 7 Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the receptacle Repair or replace immediately all electric service cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage al...

Page 3: ...conditioner is shut off wait at least two minutes before restarting it COOLER 09 llllll 1 10 7 6 e 4 1 50 4 0 3 1 3 Thermostat Control When you turn the Thermostat Control to the desired setting the Ventilation Control When this control is turned to the CLOSED position only the air thermostat will automatically control inside the room can be circulated the temperature of the indoor air and conditi...

Page 4: ...et on 9 or 10 and the Fan is set on low speed moisture may freeze on the coils and prevent the unit from cooling If this happens set the fan at high speed and the Thermostat Control to a lower number 3 Set the Ventilation Control at CLOSED For ni ttime operation During the cooler evening hours we recommend that you set the Selector Switch at LOW COOL for very quiet operation and the Thermostat Con...

Page 5: ... numbers easier to read I To remove the grille unscrew the attachment Gobs on each side of the grille Then grasp both sides of the grille and pull it forward and off To replace the grille lineup the tabs on the grille with the holes in the cabinet insert the attachment knobs and screw them finger tight Air Hlter The air filter behind the front grille should be washed at least evefi 30 days or as o...

Page 6: ...ycles on and off This is normal Fan runs continuously when Selector Switch is in Cool or Fan position This is normal Excess water may overflow in extremely hot and humid weather This is normal Air conditioner must be installed with the specified tilt to the outside for proper water disposal This is normal for a short period in areas with little humidity normal for a longer period in very humid are...

Page 7: ...o wall outlet cover OR REMOVE THE THIRD screw does not ground appliance GROUND PRONG OM unless cover screw is metal and THE POWER CORD not insulated and wall outlet is groundd through house wiring You hould have cir uit checked by a qualified electrician to make sure Use of adapter plug the outlet is properly grounded Because of potential safety When disconnecting the power hazards under certain c...

Page 8: ...metil window sash is in its final position 1 Remove the Chassis 3 Attich the cabinet to the window stool by driving pe A screws Slide the chassis out of the cabinet through the ca ine track into the by ullin the chassis forward window stool while bra cing the cabinet Remove I the screen if necessary and Type A Screw replace it after installation Cabinet Screen 4 Loosely attach the sill bracket to ...

Page 9: ...ing by required width Using a sharp knife driving upholsterers tacks through and insert the line cord into the mark the groove until the filler panel the holes in the filler panel flange notch in the cabinet Make sure the front of the chassis is flush with the becomes weak enough to break apart X Minus One Groove 3 16 Filler anel 3 Insert the cut edge of the filler panel into the cabinet side seal...

Page 10: ...aling material furnished Condemate Drain A condensate drain is provided to divert excess water when the air conditioner is installed over a doorway or sidewalk Caution Do not drill a hole in the base pan 1 Pry the cap plug from the condensate drain located on the underside of the base pan Use a 3 8 pipe tap and fully thread the condensate drain I Cap Plug k p Condensate Drain J 2 Screw a 3 8 pipe ...

Page 11: ...racing cabinet with one hand while pulling chassis out with other hand 3 Instill Cabinet in Wall 1 Remove and discard top retainer bar and cabinet side seals 2 Put cabinet in wall opening 3 Attach cabinet to wood frame w q 1 Long d Wood Screws a Drive 2 locally obtained 1 long wood screws through cabinet track into wood frame bottom II I II b Drive 11 locally obtained 1 long wood screws hrough hol...

Page 12: ...LECTRIC CUSTOMER CARE SERVICE WHAT IS N COVERED Service trips to teach you how to use the product Read your Use and Care material If you then have any questions about operating the product please contact your dealer or our Consumer Affairs office at the address below or call toll free GE Answer Cente 800 626 2000 consumer information service Improper installation If you have an installation proble...

Reviews: