background image

Through-the-Wall Instillation

. The cabinet may be installed

through the 

 in both existing

buildings and new construction.

● 

The side louvers must project

on the outdoor side of the wall.

● 

The room side of the cabinet must

project into the room at least 1“
from the finished wall.

. The cabinet must be installed

 from side to side and with a

3/8” tilt from front to rear.

 Required

See page 7.

Additional Materials

(obtain locally)

.   wood screws, 1“ long

● 

1 tube high grade caulking

compound

● 

Lintel, if required, to support

bricks or blocks above opening.

1. Prepare Wall Opening.

1. Determine size of opening.

Measure width and height of cabinet
and add 1/8” to each dimension.

18-1/2”

2. Choose the wall opening
location.  
Be sure wall receptacle

is (or will be) installed 

3. Make the opening. Frame it
to support the weight of the air
conditioner. Add metal flashing
over bottom of frame opening and

1“ 

Up 

on sides to reduce the

possibility of condensate entering
the area between the inner and
outer wall.

2. Remove Chassis from

Cabinet.

Slide chassis out of cabinet by
bracing cabinet with one hand
while pulling chassis out with other
hand.

3. Instill Cabinet in Wall.

1. Remove and discard top retainer

bar and cabinet side seals.

2. Put cabinet in wall opening.

3. Attach cabinet to wood frame.

     

 

1“ Long

Wood Screws

(a) Drive 2 locally-obtained 1“
long wood screws through cabinet

track into wood frame bottom.

I

 Drive 11 locally-obtained 1“

long wood screws 

 holes in

cabinet top and sides into wood
frame. 

 are 

 when

top retainer bar and 

 side

seals are removed. ) If frame is
oversize, use shims to eliminate

distortion.

11

 Line

Trim
Molding
(if desired)

 

 Wood Screws

o

INSIDE

4. Caulk all four sides on the
outdoor side of cabinet to prevent
moisture from getting through to
the interior wall. Use of flashing (a
piece of aluminum or galvanized
steel available at most hardware
stores) will further prevent moisture
from getting into interior walls.

5. Install wood trim molding
(obtained locally) around 
projection of cabinet, if desired.

4. Slide Chassis into
Cabinet.

Lift chassis and carefully slide it
into cabinet. Do not push on
controls or finned coils. Make sure
chassis is firmly seated toward rear
of cabinet.

5. Attach Dial Plate and
Control Knobs.

6. Attach Air 

 and

front Grille.

See page 5.

Summary of Contents for AVD14

Page 1: ...pair Service 6 Care and Cleaning 5 Safety Instructions 2 Condenser Coils 5 User Maintenance Instructions 5 Control Settings 3 4 Warranty Back Cover Electrical Requirements 7 Energy Saving Tips 2 Extension Cords 7 Grille and Cabinet 5 Grounding 7 GEAmwer Center Installation Instructions 7 11 8fi 6262000 Model AVD14 GEAppIances ...

Page 2: ...stilled in accordance with the Instillation Instructions before it is used See grounding instructions on page 7 Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the receptacle Repair or replace immediately all electric service cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage al...

Page 3: ...conditioner is shut off wait at least two minutes before restarting it COOLER 09 llllll 1 10 7 6 e 4 1 50 4 0 3 1 3 Thermostat Control When you turn the Thermostat Control to the desired setting the Ventilation Control When this control is turned to the CLOSED position only the air thermostat will automatically control inside the room can be circulated the temperature of the indoor air and conditi...

Page 4: ...et on 9 or 10 and the Fan is set on low speed moisture may freeze on the coils and prevent the unit from cooling If this happens set the fan at high speed and the Thermostat Control to a lower number 3 Set the Ventilation Control at CLOSED For ni ttime operation During the cooler evening hours we recommend that you set the Selector Switch at LOW COOL for very quiet operation and the Thermostat Con...

Page 5: ... numbers easier to read I To remove the grille unscrew the attachment Gobs on each side of the grille Then grasp both sides of the grille and pull it forward and off To replace the grille lineup the tabs on the grille with the holes in the cabinet insert the attachment knobs and screw them finger tight Air Hlter The air filter behind the front grille should be washed at least evefi 30 days or as o...

Page 6: ...ycles on and off This is normal Fan runs continuously when Selector Switch is in Cool or Fan position This is normal Excess water may overflow in extremely hot and humid weather This is normal Air conditioner must be installed with the specified tilt to the outside for proper water disposal This is normal for a short period in areas with little humidity normal for a longer period in very humid are...

Page 7: ...o wall outlet cover OR REMOVE THE THIRD screw does not ground appliance GROUND PRONG OM unless cover screw is metal and THE POWER CORD not insulated and wall outlet is groundd through house wiring You hould have cir uit checked by a qualified electrician to make sure Use of adapter plug the outlet is properly grounded Because of potential safety When disconnecting the power hazards under certain c...

Page 8: ...metil window sash is in its final position 1 Remove the Chassis 3 Attich the cabinet to the window stool by driving pe A screws Slide the chassis out of the cabinet through the ca ine track into the by ullin the chassis forward window stool while bra cing the cabinet Remove I the screen if necessary and Type A Screw replace it after installation Cabinet Screen 4 Loosely attach the sill bracket to ...

Page 9: ...ing by required width Using a sharp knife driving upholsterers tacks through and insert the line cord into the mark the groove until the filler panel the holes in the filler panel flange notch in the cabinet Make sure the front of the chassis is flush with the becomes weak enough to break apart X Minus One Groove 3 16 Filler anel 3 Insert the cut edge of the filler panel into the cabinet side seal...

Page 10: ...aling material furnished Condemate Drain A condensate drain is provided to divert excess water when the air conditioner is installed over a doorway or sidewalk Caution Do not drill a hole in the base pan 1 Pry the cap plug from the condensate drain located on the underside of the base pan Use a 3 8 pipe tap and fully thread the condensate drain I Cap Plug k p Condensate Drain J 2 Screw a 3 8 pipe ...

Page 11: ...racing cabinet with one hand while pulling chassis out with other hand 3 Instill Cabinet in Wall 1 Remove and discard top retainer bar and cabinet side seals 2 Put cabinet in wall opening 3 Attach cabinet to wood frame w q 1 Long d Wood Screws a Drive 2 locally obtained 1 long wood screws through cabinet track into wood frame bottom II I II b Drive 11 locally obtained 1 long wood screws hrough hol...

Page 12: ...LECTRIC CUSTOMER CARE SERVICE WHAT IS N COVERED Service trips to teach you how to use the product Read your Use and Care material If you then have any questions about operating the product please contact your dealer or our Consumer Affairs office at the address below or call toll free GE Answer Cente 800 626 2000 consumer information service Improper installation If you have an installation proble...

Reviews: