![GE AKTAprime plus Operating Instructions Manual Download Page 66](http://html.mh-extra.com/html/ge/aktaprime-plus/aktaprime-plus_operating-instructions-manual_128017066.webp)
Appendix B Tubing
Names in the Label column in Table B.1 refer to tubing labels in the liquid flow path
connection diagram, see Appendix A Connection diagram - Liquid flow path, on page 65.
Table B.1: Tubing specifications for ÄKTAprime plus
Volume
(μl)
I.D.
(mm)
Length
(mm)
Material
Label
Use
8.2 × 10
3
2.9
1250
FEP
A1
Inlet A11
1.1 × 10
3
2.9
170
FEP
A
Inlet A1
8.2 × 10
3
2.9
1250
FEP
B
Inlet A2
1.0 × 10
3
1.6
510
FEP
AB
Switch valve - Pump A3
66
0.75
150
PEEK
G1
Pump - Pressure monitor
53
0.75
120
PEEK
G2
Pressure monitor - Mixer
133
0.75
300
PEEK
G3
Mixer - Valve
287
0.75
650
PEEK
G4
Valve - UV (Column)
110
0.75
250
PEEK
G5
UV - Cond
7
0.50
38
PEEK
Union,
1/16" male /
1/16" male
Cond - Flow restrictor
243
0.75
550
PEEK
G6
Flow restrictor – Frac. coll.
181
0.75
410
PEEK
F1
Frac. tubing
785
1.0
1000
PEEK
W1, W2, W3
Waste
66
ÄKTAprime plus Operating Instructions 28-9597-89 AB