47
-
Indoor fan motor burned out or there
is wire breakage or failure of
overheating protector
Replace fan motor or components
with failure
The internal overheating protector
frequently breaks as overheating is
caused by abnormity of motor
Replace fan motor
Wrong line connection
Correctly connect lines according
to electrical diagram
Open circuit or damage of fan
capacitor
Replace it withfan capacitor of the
same model and spec
When air supply
mode is
selected, the fan
does not
operate
Outdoor fan motor is damaged
Replace fan motor
Wrong line connection
Correctly connect lines according
to electrical diagram
Outdoor fan capacitor is damaged
Replace fan capacitor
When in cooling
or heating mode,
compressor
operates but
outdoor fan does
not operate
Compressor failure
Replace Compressor
Operating capacitor of compressor is
damaged
Replace capacitor
Voltage is too low or too high
It is suggested to equip voltage
regulator
Wrong line connection
Correctly connect lines according
to electrical diagram
When in cooling
or heating mode,
outdoor fan
operates but
compressor
does not operate
Failure of protector itself
Use universal meter to check if
contacts of compressure not
overheated are conducting;
replace protector in case of
non-conducting conditions
Insufficient or too much refrigerant
Adjust refrigerant amount
Capillary is blocked so air intake
temperature is too high
Replace capillary
Compressor does not operate
smoothly (seized or jammed), air
discharge valve is damaged
Replace Compressor
Failure of protector itself
Replace protector
Compressor is
overheated so
protector is
activated
Torque of swing motor is insufficient
Wrong line connection
Fisrtly check if line connections
have fault, if no, replace
components at failure position
Controller is damaged (IC2003 is
damaged, swing relay cannot close
Swing louver
does not run
Summary of Contents for AIR F24
Page 2: ... 2 ...
Page 3: ... 3 ...
Page 5: ... 5 M Mo od de el l R Re em ma ar rk ks s GE AIR F34 3PH 400V 50Hz R407C ...
Page 6: ... 6 M Mo od de el l R Re em ma ar rk ks s GE AIR F41 3PH 400V 50Hz R407C ...
Page 12: ... 12 Applicable to GE AIR F34 IN GE AIR F41 IN ...
Page 14: ... 14 Applicable to GE AIR F41 OUT Unit mm Bolt Nut Wrench ...
Page 16: ... 16 GE AIR F24 GE AIR F34 6 6 E El le ec ct tr ri ic ca al l D Di ia ag gr ra am m ...