Disassemble Axial Flow Fan
Use spanner to remove the nut at the fan to
remove the axial flow fan. (Fig 8-56)
Nut
Axial Flow Fan
(Fig 8-56)
Disassemble Outdoor Motor
Motor
Screw off the four tapping screws fixing the
motor, pull out the motor lead-out cable plug,
and remove the motor. Screw off the two
tapping screws fixing the motor support, and
pull the motor support upward to remove it.
(Fig 8-57)
Screw Fixing the Motor
Motor Cable
Motor Support
Fixing Screw
(Fig 8-57)
Disassemble 4-Way Valve
(
Only Heating and Cooling Unit has such
valve
)
Screw off the holding nut of the 4-way valve
coil and remove the coil. Use wet cotton cloth
to wrap the 4-way valve, unsold the four
soldering points connecting the 4-way valve,
and remove the 4-way valve. Be quick during
the unsoldering process, pay attention to keep
the wrapping cloth wet and do not allow the
soldering flame to burn the compressor
lead-out cable. (Fig 8-58)
4-Way Valve
Soldering
Point
(Fig 8-58)