60
—
Operation procedures/pictures
Disassembling axial flow fan
Screw off the fixing nut of axial flow fan with a
spanner to pull outward the axial flow fan as
shown in Fig. 8-55.
fixing nut
Fig. 8-55
Disassembling the motor and motor support
Screw off the motor fixing bolt on the motor
bracket pull out the motor backwards. Then
screw off the tapping screws that fix the motor
support, lift it upward and take out the motor
support as shown in Fig. 8-56.
Motor bracket
Fixing bolt of motor bracket
Fig. 8-56
Disassembling Four-way valve
Screw off the fixing nut of the coils of four-way
valves (2 pieces) and remove the coil. Wrap
the four-way valve with wet sponge and weld
off the weld joints on the four-way valve to
take off the four-way valve. The welding
process should be performed as quick as
possible, ensure that the wrapped spun cotton
should be moistened all along; ensure that the
pin cords etc. of compressor must not be burnt
out by thin flame. (Note: it is required to
completely discharge freon firstly.)as shown in
Fig. 8-57.
Fig .8-57
Axial flow fan
Motor fixing bolt
Four-way valve
Welded point
Summary of Contents for AIR 326
Page 2: ... 1 Summary and features Model Remark PRO AIR 107 IN PRO AIR 107 OUT 1Ph 230V 50Hz R410A 1 ...
Page 4: ... 3 Model Remark PRO AIR 218 IN PRO AIR 218 OUT 1Ph 230V 50Hz R410A ...
Page 5: ... 4 Model Remark GE AIR 326 IN1 GE AIR 326 IN2 GE AIR 326 OUT 1Ph 230V 50Hz R407C ...
Page 6: ... 5 Model Remark GE AIR 428 IN GE AIR 428 OUT 1Ph 230V 50Hz R407C ...
Page 20: ... 19 4 2 Outline and installation dimensions of indoor unit 20 Handle 60cm Bolt Nut Spanner ...
Page 71: ... 70 Explosive view and parts list Explosive view of parts and components of indoor unit 9 ...
Page 75: ... 74 Explosive view of parts and components of outdoor unit ...
Page 77: ... 76 Explosive view of parts and components of outdoor unit frequency converter ...
Page 79: ... 78 Explosive view of parts of outdoor unit one driving two ...
Page 81: ... 80 Explosive view of parts of outdoor unit one driving three ...
Page 83: ... 82 Explosive view of parts of outdoor unit one driving four ...
Page 101: ... 100 ...