42
—
Operation procedures/pictures
Disassembling the electric box
Firstly screw off 2 screws at the indicator board
and disassemble the indicator board. Then, pull
away the terminals of motor. Screw off grounding
screw and 2 screws fixing the electric box with a
screw driver. Open a latch of the electric box to
remove the electric box. as shown in Fig.8-7, 8-8.
Disassembling evaporator assembly
Firstly use a screwdriver to unscrew the screws in
the rear pipe-clamping bar of evaporator. Remove
the rear pipe clamp bar.
Unscrew the 2 screws at the right side of
evaporator.
Unscrew the screw on the left side of the
evaporator, and loosen the clasp. Turn the
evaporator for a certain angle, and remove the
evaporator as shown in Fig.8-8, 8-9, 8-10, 8-11.
Screw
Indicator board
Fig.8-7
Screw
Grounding screws Clamp
Fig.8-8
Rear pipe
clip board
Fig.8-9
Summary of Contents for AIR 326
Page 2: ... 1 Summary and features Model Remark PRO AIR 107 IN PRO AIR 107 OUT 1Ph 230V 50Hz R410A 1 ...
Page 4: ... 3 Model Remark PRO AIR 218 IN PRO AIR 218 OUT 1Ph 230V 50Hz R410A ...
Page 5: ... 4 Model Remark GE AIR 326 IN1 GE AIR 326 IN2 GE AIR 326 OUT 1Ph 230V 50Hz R407C ...
Page 6: ... 5 Model Remark GE AIR 428 IN GE AIR 428 OUT 1Ph 230V 50Hz R407C ...
Page 20: ... 19 4 2 Outline and installation dimensions of indoor unit 20 Handle 60cm Bolt Nut Spanner ...
Page 71: ... 70 Explosive view and parts list Explosive view of parts and components of indoor unit 9 ...
Page 75: ... 74 Explosive view of parts and components of outdoor unit ...
Page 77: ... 76 Explosive view of parts and components of outdoor unit frequency converter ...
Page 79: ... 78 Explosive view of parts of outdoor unit one driving two ...
Page 81: ... 80 Explosive view of parts of outdoor unit one driving three ...
Page 83: ... 82 Explosive view of parts of outdoor unit one driving four ...
Page 101: ... 100 ...