53
—
8.4
Disassembling procedures for outdoor unit
Suitable for PRO AIR I109 IN / PRO AIR I109 OUT, PRO AIR I112 IN / PRO AIR I112 OUT
Operation procedures/pictures
Disassemble the top cover
Screw off the one piece of fixing screw that fixes
the handle with screwdriver and push down with
strength to take out the handle.
Screw off the 3 pieces of screws around the top
cover and then lift it upward to take out the top
cover as shown in Fig.8-36.
Disassembling net cover
Screw off 4 taping screws at the rear sideboard
and valve support chassis and condensor
sideboard to remove the net cover as shown in
Fig.8-37.
Disassembling panel assembly
Screw off the 5 pieces of tapping screws at the
valve support chassis and sideboard of the
condenser to take off panel assembly as shown
in Fig.8-38.
Top cover Screw Screw Handle
Fig.8-36
Rear grill
Screw
Fig.8-37
Panel
Screw
Fig.8-38
Summary of Contents for AIR 326
Page 2: ... 1 Summary and features Model Remark PRO AIR 107 IN PRO AIR 107 OUT 1Ph 230V 50Hz R410A 1 ...
Page 4: ... 3 Model Remark PRO AIR 218 IN PRO AIR 218 OUT 1Ph 230V 50Hz R410A ...
Page 5: ... 4 Model Remark GE AIR 326 IN1 GE AIR 326 IN2 GE AIR 326 OUT 1Ph 230V 50Hz R407C ...
Page 6: ... 5 Model Remark GE AIR 428 IN GE AIR 428 OUT 1Ph 230V 50Hz R407C ...
Page 20: ... 19 4 2 Outline and installation dimensions of indoor unit 20 Handle 60cm Bolt Nut Spanner ...
Page 71: ... 70 Explosive view and parts list Explosive view of parts and components of indoor unit 9 ...
Page 75: ... 74 Explosive view of parts and components of outdoor unit ...
Page 77: ... 76 Explosive view of parts and components of outdoor unit frequency converter ...
Page 79: ... 78 Explosive view of parts of outdoor unit one driving two ...
Page 81: ... 80 Explosive view of parts of outdoor unit one driving three ...
Page 83: ... 82 Explosive view of parts of outdoor unit one driving four ...
Page 101: ... 100 ...