52
—
Operation procedures/pictures
Disassemblling big and small valves
Screw off 2bolts that fix the big valve, weld off
the welding point between the big valve and
the air return pipe to take down the big valve.
(Note: when welding off the welding spots,
wrap the big valve with wet cloth completely to
avoid high-temperature from damaging the
valve body.)
Screw off 2 bolts that fix the small valve, weld
off the welding point between the small vale
and the forked type pipe and take down the
small valve as shown in Fig.8-34.
Disassembling compressor
Screw off 3 nuts with wash at the base legs of
compressor (Remarks: it is required to firstly
discharge completely the freon.
)
Weld off the
welding spots as shown in the sucking and
exhausted pipings of the compressor. Remove
away carefully the pipings and remove the
compressor as shown in Fig.8-35.
Small valve gate
Big valve gate
Bolt
Fig.8-34
Compressor bolt
Fig.8-35
Summary of Contents for AIR 326
Page 2: ... 1 Summary and features Model Remark PRO AIR 107 IN PRO AIR 107 OUT 1Ph 230V 50Hz R410A 1 ...
Page 4: ... 3 Model Remark PRO AIR 218 IN PRO AIR 218 OUT 1Ph 230V 50Hz R410A ...
Page 5: ... 4 Model Remark GE AIR 326 IN1 GE AIR 326 IN2 GE AIR 326 OUT 1Ph 230V 50Hz R407C ...
Page 6: ... 5 Model Remark GE AIR 428 IN GE AIR 428 OUT 1Ph 230V 50Hz R407C ...
Page 20: ... 19 4 2 Outline and installation dimensions of indoor unit 20 Handle 60cm Bolt Nut Spanner ...
Page 71: ... 70 Explosive view and parts list Explosive view of parts and components of indoor unit 9 ...
Page 75: ... 74 Explosive view of parts and components of outdoor unit ...
Page 77: ... 76 Explosive view of parts and components of outdoor unit frequency converter ...
Page 79: ... 78 Explosive view of parts of outdoor unit one driving two ...
Page 81: ... 80 Explosive view of parts of outdoor unit one driving three ...
Page 83: ... 82 Explosive view of parts of outdoor unit one driving four ...
Page 101: ... 100 ...