45
—
8.2
Disassembling procedure of outdoor unit 20
Operation procedures/pictures
Disassembling top cover and handle
Screw off one fixing screw that fixes the handle
with screwdriver to take out the handle. Screw
off 3 screws around the top cover to remove
the top cover as shown in Fig.8-15.
Disassembling the rear grill
Screw off 4 screws around the rear grill with a
screw driver to remove the rear grill as shown
in Fig.8-16.
Remove the front panel
Screw off 6 screws fixing the front panel with a
screw driver to remove front panel as shown in
Fig.8-17.
Top cover
Handle
Screw
Fig. 8-15
Rear grill
Fig.8-16
Screw
Fig.8-17
Summary of Contents for AIR 326
Page 2: ... 1 Summary and features Model Remark PRO AIR 107 IN PRO AIR 107 OUT 1Ph 230V 50Hz R410A 1 ...
Page 4: ... 3 Model Remark PRO AIR 218 IN PRO AIR 218 OUT 1Ph 230V 50Hz R410A ...
Page 5: ... 4 Model Remark GE AIR 326 IN1 GE AIR 326 IN2 GE AIR 326 OUT 1Ph 230V 50Hz R407C ...
Page 6: ... 5 Model Remark GE AIR 428 IN GE AIR 428 OUT 1Ph 230V 50Hz R407C ...
Page 20: ... 19 4 2 Outline and installation dimensions of indoor unit 20 Handle 60cm Bolt Nut Spanner ...
Page 71: ... 70 Explosive view and parts list Explosive view of parts and components of indoor unit 9 ...
Page 75: ... 74 Explosive view of parts and components of outdoor unit ...
Page 77: ... 76 Explosive view of parts and components of outdoor unit frequency converter ...
Page 79: ... 78 Explosive view of parts of outdoor unit one driving two ...
Page 81: ... 80 Explosive view of parts of outdoor unit one driving three ...
Page 83: ... 82 Explosive view of parts of outdoor unit one driving four ...
Page 101: ... 100 ...