9.2.3 Power Card Mounting Plate
1.
Disconnect two fast-on connectors from fuse block attached to power card mounting plate flange.
2.
Disconnect from power card connectors MK100, MK103, MK104, MK105, MK106, and MK110.
3.
Disconnect three cable connectors (6-pin, 8-pin, and 12-pin) from power card mounting panel flange. Cable connectors disconnect from back side of
flange.
4.
Remove power card mounting plate by removing four retaining nuts (8mm) securing plate.
NOTE
: At this point soft charge cards are accessible for changing fuses. Two soft charge cards are present for units with two inverter modules, three
soft charge cards for units with three inverter modules.
1
2
4
3
5
6
1
Power card mounting plate (step 4)
4
Fuse block (step 1)
2
Power card (step 2)
5
Power card mounting plate flange
3
Cable connectors (step 3)
6
Attaching screw (step 4)
High Power Service Manual for Unit Sizes 6x
123