8.2.6 High Frequency Board
1.
Remove upper capacitor bank assembly in accordance with instructions.
2.
Disconnect cable from connector MK100 on high frequency board.
3.
Remove two screws (T25) from high frequency board.
4.
Remove one nut (8mm) from high frequency board standoff and remove board.
Reassembly is done in reverse order.
1
2
3
130BX258.10
1
T25 screw (step 3)
3
8mm retaining nut (step 4)
2
High frequency board
High Power Service Manual for Unit Sizes 6x
114
8
Summary of Contents for AF-650 GP Series
Page 31: ...High Power Service Manual for Unit Sizes 6x 30 3...
Page 41: ...Illustration 3 7 Inverter section High Power Service Manual for Unit Sizes 6x 40 3...
Page 43: ...Illustration 3 8 Brake option High Power Service Manual for Unit Sizes 6x 42 3...
Page 97: ...High Power Service Manual for Unit Sizes 6x 96 7...
Page 111: ...High Power Service Manual for Unit Sizes 6x 110 8...
Page 121: ...High Power Service Manual for Unit Sizes 6x 120 9...
Page 134: ...11 Block Diagrams High Power Service Manual for Unit Sizes 6x 133 11...